Catphan Phantoms for the routine quality assurance for CT scanners
Fast and easy positioning and universal mount make the Catphan® phantoms range ideal for routine quality assurance of any CT scanner.
Comprehensive CT performance measurements
Comprehensive CT performance measurements, internationally recognised for measuring the maximum obtainable performance of axial, spiral, multislice, conebeam and volume CT scanners.
Modular Construction
The Catphan® modular design allows test modules to be interchanged.
As your testing needs change and new modules are developed you can upgrade test modules that are compatible with your Catphan® system. Additionally, the Catphan® system is ideal for travelling physicists and engineers who conduct comprehensive evaluations of CT scanners at multiple locations as they are easily transportable and no draining is required between uses.
Durable Design
Solid-cast construction eliminates material absorption of water, freezing and leaks associated with water bath phantoms, as well as problems related to varied water sources.
Catphan® 500, 600, & 700
Catphan® 500, 600, & 700 are designed for comprehensive evaluation
of axial, spiral, multislice, conebeam, and volume CT scanners.
Catphan 500 Phantom
Complete Catphan including housing and case equipped with the following test modules:
- Slice width, sensitometry and pixel size.
- 21 line pair high resolution and point source.
- Subslice and supra-slice low contrast.
- Solid image uniformity module
Catphan 600 Phantom
Complete Catphan including housing and case, equipped with the following test modules:
- Slice width, sensitometry and pixel size.
- Bead geometry module.
- 21 line pair high resolution and point source.
- Subslice and supra-slice low contrast.
- Solid image uniformity module.
Catphan 700 Phantom
Complete Catphan including housing and case, equipped with the following test modules:
- Geometry sensitometry and point source module.
- 30 line pair high resolution and point source.
- Subslice and supra-slice low contrast.
- Wave insert.
- Bead insert.
Individual Catphan sections are available on request.
Tests Summary
- Scan slice geometry (slice width and slice sensitivity profile).
- High resolution (up to 30 line pairs per cm).
- Phantom position verification.
- Patient alignment system check.
- Low contrast sensitivity.
- Comparative subslice and supra-slice low contrast sensitivity.
- Spatial uniformity.
- Scan incrementation.
- Noise (precision) of CT systems.
- Circular symmetry.
- Sensitometry (linearity).
- Pixel (matrix) size.
- Point spread function and modulation transfer.
function (MTF) for the x, y, and z axes.